Menu
Quick Search
Enter locomotive number in the box below and press 'Go'!
In Touch
Donations
Counter
Visitor Statistics
|
» 45 Online
» 2834 Today
» 6417 Yesterday
» 31069 Week
» 31069 Month
» 2071973 Year
» 8608180 Total
|
Record: 71951 (21/04/2026)
(Free MySQL Counter)
|
GNR/LNER Gresley "K2" Class 2-6-0
Class Types
| GNR Class |
H3 |
| LNER Class |
K2 |
General
| Designer |
Sir Nigel Gresley |
| Introduced |
1913 |
| Pre-Grouping Company |
Great Northern Railway |
| Grouping Company |
London and North Eastern Railway |
| Description (1957) |
Class K2. Gresley 5'8" 2-cylinder 2-6-0's, built 1912-21. Since 1925 a number of the class have been transferred to Scotland and received side-window cabs, most of them at the same time being named after Lochs. Scrapping commenced 1955. |
| Wheel Arrangement |
2-6-0 |
| Number Built as K2 |
65 |
| First in Service |
04/1914 |
| Last in Service |
22/06/1962 |
| Manufacturers |
|
| Orders |
|
|
|
|
Power
|
K2/1 |
K2/2 |
| Variant Introduced |
1920 |
1914 |
| Tractive Effort |
23,400lbs |
As K2/1 |
| Outside Cylinders |
20" x 26" (2 off) |
As K2/1 |
| Outside Valves |
10"Piston |
As K2/1 |
| Outside Motion |
Walschaerts |
As K2/1 |
Wheels
|
K2/1 |
K2/2 |
| Pony |
3' 2" |
As K2/1 |
| Drivers |
5' 8" |
As K2/1 |
| Locomotive Wheelbase |
24' 10" |
25' 2" |
| Tender Wheelbase |
13' |
As K2/1 |
| Descriptive Wheelbase |
8' 11" + 7' 3" + 9' 0" + 9' 3¾" + 7' 0" + 6' 0" = 56' 11½" |
8' 11" + 7' 3" + 9' 0" + 9' 5½" + 7' 0" + 6' 0" = 57' 1¼" |
Dimensions
|
K2/1 |
K2/2 |
| Length (over buffers) |
46' 101⁄4" |
As K2/1 |
| Weight (in running order) |
106t 16cwt |
As K2/1 |
| Weight (loco only) |
63t 14cwt |
64t 8cwt |
| Adhesive Weight |
53t 8cwt |
53t 18cwt |
| Maximum Axle Load |
18t 12cwt |
18t 16cwt |
| Water Capacity |
3,500gal |
As K2/1 |
| Coal Capacity |
6t 10cwt |
As K2/1 |
Boiler & Firebox
|
K2/1 |
K2/2 |
| Boiler Diagram |
3 |
As K2/1 |
| Boiler Max Diameter |
5' 6" |
As K2/1 |
| Boiler Barrel Length |
11' 111⁄2" |
As K2/1 |
| Boiler Pressure |
180lbs |
As K2/1 |
| Boiler Pitch |
8' 81⁄2" |
As K2/1 |
| Firebox Length |
8' 6" |
As K2/1 |
| Firebox Grate Area |
24ft2 |
As K2/1 |
| Firebox Heating Surface |
152ft2 |
As K2/1 |
| Tube Number |
197 |
As K2/1 |
| Tube Diameter |
13⁄4" |
As K2/1 |
| Tube Area |
1082ft2 |
As K2/1 |
| Flue Elements |
24 |
As K2/1 |
| Flue Diameter |
51⁄4" |
As K2/1 |
| Flue Area |
395.5ft2 |
As K2/1 |
| Total Evaporative Area |
1629.5ft2 |
As K2/1 |
| Superheater Elements |
24 |
As K2/1 |
| Superheater Element Diameter |
11⁄4" |
As K2/1 |
| Superheater Element Area |
305ft2 |
As K2/1 |
| Total Heating Area |
1934.5ft2 |
As K2/1 |
|